Division (d) Measurement Procedure
To measure time, an ordinary stopwatch and timing to a resolution of one second is sufficient. All power figures are to be recorded in watts (W). Table 9 outlines the steps of the OM test procedure.
Service/maintenance modes (including colour calibration) generally should not be included in measurements. Any adaptation of the procedure needed to exclude such modes that occur during the test must be noted.
As stated above, all power measurements are to be made in accordance with IEC 62301. Depending on the nature of the mode, IEC 62301 provides for instantaneous power measurements, five-minute accumulated energy measurements, or accumulated energy measurements over periods long enough to properly assess cyclical consumption patterns. Regardless of the method, only power values should be reported.
Table 9
OM Test Procedure
| Step | Initial State | Action | Record |
|---|---|---|---|
| 1 | Off | Plug the unit into meter. Turn on unit. Wait until unit indicates it is in Ready mode. | — |
| 2 | Ready | Print, copy, or scan a single image. | — |
| 3 | Ready | Measure Ready power. | Ready power |
| 4 | Ready | Wait default delay time to Sleep. | Sleep default delay time |
| 5 | Sleep | Measure Sleep power. | Sleep power |
| 6 | Sleep | Wait default delay time to Auto-off. | Auto-off default delay time |
| 7 | Auto-off | Measure Auto-off power. | Auto-off power |
| 8 | Off | Manually turn device off. Wait until unit is off. | — |
| 9 | Off | Measure Off power. | Off power |